Southwire® 26020008-6 In-Line Protected GFCI Tri-Cord, 120 VAC, 15 A, 1 Pole, 3 Wires, 12/3, Yellow

13152100 MFG #: 26020008-6
$0.00 / Each
In Stock
  • Type: In-Line Protected
  • Voltage Rating: 120
  • Amperage Rating: 15
  • Frequency Rating: 50/60
  • Number of Poles: 1, 2
  • Number of Wires: 3
  • NEMA Rating: NEMA 5-15P/5-15R
  • Enclosure: Rainproof
  • Temperature Rating: -35 to 66
  • Material: Heavy Impact Resistant Polymer, Polymer
  • Color: Yellow
  • Dimensions: 2 ft L x 4.75 in W x 1.89 in H
GFCI Tri-Cord, In-Line Protected, 120 VAC, 15 A, 50/60 Hz, 1 Pole, 3 Wires, NEMA 5-15P/5-15R, Rainproof Enclosure, -35 to 66 deg C, Polymer, Yellow, 2 ft L x 4.75 in W x 1.89 in H
QTY
  • In line sets feature
  • In line sets feature a heavy duty molded T-head with three receptacles
  • To prevent unmonitor
  • To prevent unmonitored equipment startup, manual reset is required after GFCI trip and pow
  • 4 to 6 ma trip level
  • 4 Ohm typical grounded neutral
  • 4 Ohm typical ground
  • Operates within normal limits with 0.5 volts injected on power line 150 kHz to 230 MHz
  • Operates within norm
  • 3000 operations mini
  • 3000 operations minimum endurance
  • Six times rated over
  • Six times rated overload current
  • 5% maximum trip leve
  • 5% maximum trip level variation
  • 1500 VRMS - 1 min in
  • 1500 VRMS - 1 min insulation voltage
  • Lighted indicator po
  • Lighted indicator power on indication
  • 12 ga cord is ideal
  • 12 ga cord is ideal for outdoor
In line sets feature a heavy duty molded T-head with three receptacles
In line sets feature a heavy duty molded T-head with three receptacles
To prevent unmonitored equipment startup, manual reset is required after GFCI trip and power outage
To prevent unmonitored equipment startup, manual reset is required after GFCI trip and power outage
4 to 6 ma trip level
4 Ohm typical grounded neutral
4 Ohm typical grounded neutral
Operates within normal limits with 0.5 volts injected on power line 150 kHz to 230 MHz
Operates within normal limits with 0.5 volts injected on power line 150 kHz to 230 MHz
3000 operations minimum endurance
3000 operations minimum endurance
Six times rated overload current
Six times rated overload current
5% maximum trip level variation
5% maximum trip level variation
1500 VRMS - 1 min insulation voltage
1500 VRMS - 1 min insulation voltage
Lighted indicator power on indication
Lighted indicator power on indication
12 ga cord is ideal for outdoor