DeWALT® Power-Stud+® SD1 7442SD1 Expansion Wedge Anchor, 3/4 in Dia, 5-1/2 in OAL, 3 in L Thread, Carbon Steel, Zinc Plated

08375512 MFG #: 7442SD1
$0.00 / Box of 20
In Stock
  • Type: Expansion
  • Series: Wedge-All®
  • Diameter: 3/4
  • Overall Length: 5-1/2
  • Thread Length: 3, 3-5/8
  • Material: Carbon Steel
  • Finish: Zinc Plated
  • Minimum Embedment Depth: 3-3/8
  • Head Size: 1-1/8
  • Drill Size: 3/4
  • Head Type: Hex
  • Thread Size: 3/4-10
  • Head Style: Hex
  • Thread Type: UNC
  • Shear Strength: 12685, 792
  • Tensile Strength: 544, 7860
DeWALT® Power-Stud+® SD1 Wedge Anchor, Expansion, 3/4 in Dia, 5-1/2 in Overall Length, 3 in Thread Length, Carbon Steel, Zinc Plated, 3-3/8 in Minimum Embedment Depth, 3/4 in Drill, 3/4-10, Hex Head, UNC, 12685 lb Shear Strength, 7860 lb Tensile
QTY
  • Code listed under IB
  • Code listed under IBC/IRC for grout-filled CMU per ICC-ESESR-1396
  • Consistent performan
  • Consistent performance in high and low strength concrete
  • One-piece, wrap-arou
  • One-piece, wrap-around clip ensures uniform holding capacity
  • Nominal drill bit si
  • Nominal drill bit size is the same as the anchor diameter
  • Threaded end is cham
  • Threaded end is chamfered for ease of starting nut
  • Anchor can be instal
  • Anchor can be installed through standard fixture holes
  • Available in a wide range of diameters and lengths
  • Anchor design allows for follow-up expansion after setting under tensile loading
  • Carbon steel ASTM A563 grade A nut
  • Length ID code and i
  • Length ID code and identifying marking stamped on head of each anchor
  • The minimum concrete thickness is 1-1/2 times the embedment depth
  • Anchor design allows
  • Anchor design allows for follow-up expansion after setting under tensile loading ultimate
  • The allowable loads are based on a safety factor of 4
  • Normal weight concre
  • Normal weight concrete, structural sand-light weight concrete, concrete over steel deck an
  • The allowable loads
  • 7/8 in minimum fixture hole
  • 150 ft-lb installation torque
  • 6760 lb at 2000 psi, 9960 lb at 4000 psi ultimate tension loads and 1690 lb at 2000 psi, 2
  • 11360 lb at 2000 psi ultimate shear loads and 2840 lb at 2000/3000/4000 psi for concrete
  • Anchor body material meets minimum 70000 psi tensile strength
• Code listed under IBC/IRC for grout-filled CMU per ICC-ESESR-1396
Code listed under IBC/IRC for grout-filled CMU per ICC-ESESR-1396
Consistent performance in high and low strength concrete
Consistent performance in high and low strength concrete
• One-piece, wrap-around clip ensures uniform holding capacity
One-piece, wrap-around clip ensures uniform holding capacity
Nominal drill bit size is the same as the anchor diameter
Nominal drill bit size is the same as the anchor diameter
• Threaded end is chamfered for ease of starting nut
Threaded end is chamfered for ease of starting nut
Anchor can be installed through standard fixture holes
Anchor can be installed through standard fixture holes
Available in a wide range of diameters and lengths
Anchor design allows for follow-up expansion after setting under tensile loading
Carbon steel ASTM A563 grade A nut
Length ID code and identifying marking stamped on head of each anchor
Length ID code and identifying marking stamped on head of each anchor
The minimum concrete thickness is 1-1/2 times the embedment depth
Anchor design allows for follow-up expansion after setting under tensile loading ultimate pullout 5440 lb
Anchor design allows for follow-up expansion after setting under tensile loading ultimate pullout 5440 lb
The allowable loads are based on a safety factor of 4
Normal weight concrete, structural sand-light weight concrete, concrete over steel deck and grouted concrete masonry are applicable materials
Normal weight concrete, structural sand-light weight concrete, concrete over steel deck and grouted concrete masonry are applicable materials
• The allowable loads are based on a safety factor of 4
7/8 in minimum fixture hole
150 ft-lb installation torque
6760 lb at 2000 psi, 9960 lb at 4000 psi ultimate tension loads and 1690 lb at 2000 psi, 2090 lb at 3000 psi, 2490 lb 4000 allowable tension load psi for concrete
11360 lb at 2000 psi ultimate shear loads and 2840 lb at 2000/3000/4000 psi for concrete
Anchor body material meets minimum 70000 psi tensile strength