Southwire® Surge Guard® 14880023-6 Type SJTW-A Heavy Duty Right Angle GFCI Plug Tri-Cord, 120 VAC, 15 A, 12 AWG Conductor, 3 Outlets

13114880 MFG #: 14880023-6
Southwire® Surge Guard® GFCI Plug Tri-Cord, Type SJTW-A Heavy Duty Right Angle, 120 VAC, 15 A, 50/60 Hz, 12 AWG Conductor, 3 Outlets, 3 Conductors, -35 to 66 deg C Operating, NEMA 5-15R Receptacle, NEMA 5-15P Plug, Polymer, Yellow, 2 ft L x 4-3/4 in W
  • Heavy duty molded T-head with three receptacles
  • The gfci is an integral part of male plug
  • Provides protection for the extra heavy duty cord and three attached tools
  • 12 gauge cord is ideal for outdoor rugged construction type environments
  • To prevent unmonitored equipment startup, manual reset is required after GFCI trip and pow
  • Provides compliance with national electric code (NEC 2008) article 590.6 for temporary ins
  • 4 to 6 ma trip level
  • 4 Ohm typical grounded neutral
  • Less than 25 ms trip response time for ground fault and grounded neutral trip
  • 3 kV ringwave test and 4 kV/2 kA surge immunity test voltage surge withstand
  • Operates within normal limits with 0.5 volts injected on power line 150 kHz to 230 MHz rad
  • 3000 operations minimum endurance
  • Six times rated current overload current
  • 5% maximum trip level variation effect of 10 A turn DC shock on ground fault trip
  • 1500 Vrms 1 min insulation voltage
  • Mechanical indicator
  • Manual reset
  • Heavy impact resistant polymer material
Heavy duty molded T-head with three receptacles
The gfci is an integral part of male plug
Provides protection for the extra heavy duty cord and three attached tools
12 gauge cord is ideal for outdoor rugged construction type environments
To prevent unmonitored equipment startup, manual reset is required after GFCI trip and power outage
Provides compliance with national electric code (NEC 2008) article 590.6 for temporary installations
4 to 6 ma trip level
4 Ohm typical grounded neutral
Less than 25 ms trip response time for ground fault and grounded neutral trip
3 kV ringwave test and 4 kV/2 kA surge immunity test voltage surge withstand
Operates within normal limits with 0.5 volts injected on power line 150 kHz to 230 MHz radio frequency noise susceptibility
3000 operations minimum endurance
Six times rated current overload current
5% maximum trip level variation effect of 10 A turn DC shock on ground fault trip
1500 Vrms 1 min insulation voltage
Mechanical indicator
Manual reset
Heavy impact resistant polymer material