DeWALT® Smart Di™ 6306SD-PWR Internally Threaded Expansion Anchor, 3/8 in, Carbon Steel, 1/2 in Drill, 1-9/16 in D Min Embedment

08317205 MFG #: 6306SD-PWR
$0.00 / EACH
In Stock
  • Type: Internally Threaded, Smooth Wall, Threaded
  • Series: Smart DI+™
  • Bolt/Rod Size: 3/8
  • Thread Size: 3/8-16
  • Material: Carbon Steel
  • Drill Size: 1/2
  • Minimum Embedment Depth: 1-9/16
  • Thread Length: 5/8 in
  • Thread Type: UNC
  • Overall Length: 1-9/16, 1-9/16 in
  • Shear Strength: 810 lb at 2000 psi/925 lb at 3000 psi/1040 lb at 4000 psi for Concrete
  • Tensile Strength: 600 lb at 2000 psi, 795 lb at 3000 psi, 990 lb at 4000 psi for Concrete
  • Finish: Zinc Plated
DeWALT® Smart Di™ Expansion Anchor, Internally Threaded, 3/8 in Bolt/Rod, 3/8-16 Thread, Carbon Steel, 1/2 in Drill, 1-9/16 in Minimum Embedment Depth, UNC Thread, 1-9/16 in Overall Length
QTY
  • Lipped edge (DIAS) eliminates need for precisely drilled hole depth
  • Installs with reduced effort compared to traditional drop-in style anchors
  • Available in coil-thread version for 1/2 in and 3/4 in coil-threaded rod
  • Setting indicator ma
  • Can be installed using the manual setting tool or Smart DI+™ system with a hammer drill
  • 2600 to 2700 deg F freezing/melting point
  • Expander plug meets minimum 50000 psi tensile strength
  • Internally threaded anchor for easy bolt removability and service work
  • Anchor body meets minimum 70000 psi tensile
  • Anchor can be installed through standard fixture holes
  • The allowable loads are based on a safety factor of 4
  • 10 ft-lbs tightening torque
  • The minimum concrete thickness is 1-1/2 times the embedment depth
Lipped edge (DIAS) eliminates need for precisely drilled hole depth
Installs with reduced effort compared to traditional drop-in style anchors
Available in coil-thread version for 1/2 in and 3/4 in coil-threaded rod
Setting indicator makes identification of properly set anchors easy (when installed using the smart tool and smart bit)
Can be installed using the manual setting tool or Smart DI+™ system with a hammer drill
2600 to 2700 deg F freezing/melting point
Expander plug meets minimum 50000 psi tensile strength
Internally threaded anchor for easy bolt removability and service work
Anchor body meets minimum 70000 psi tensile
Anchor can be installed through standard fixture holes
The allowable loads are based on a safety factor of 4
10 ft-lbs tightening torque
The minimum concrete thickness is 1-1/2 times the embedment depth