DeWALT® Power-Stud+® SD1 7432SD1 Expansion Wedge Anchor, 5/8 in Dia, 4-1/2 in OAL, 2-1/2 in L Thread, Carbon Steel, Zinc Plated

08317059 MFG #: 7432SD1
$0.00 / Box of 25
In Stock
  • Type: Expansion
  • Series: Wedge-All®
  • Diameter: 5/8
  • Overall Length: 4-1/2
  • Thread Length: 2-1/2, 2-7/8
  • Material: Carbon Steel
  • Finish: Zinc Plated
  • Minimum Embedment Depth: 2-3/4
  • Head Size: 15/16
  • Drill Size: 5/8
  • Head Type: Hex
  • Thread Size: 5/8-11
  • Head Style: Hex
  • Thread Type: UNC
  • Shear Strength: 1699, 6815
  • Tensile Strength: 120, 5440
DeWALT® Power-Stud+® SD1 Wedge Anchor, Expansion, 5/8 in Dia, 4-1/2 in Overall Length, 2-1/2 in Thread Length, Carbon Steel, Zinc Plated, 2-3/4 in Minimum Embedment Depth, 5/8 in Drill, 5/8-11, Hex Head, UNC, 6815 lb Shear Strength, 5440 lb Tensile
QTY
  • Consistent performan
  • Code listed under IBC/IRC for grout-filled CMU per ICC-ESESR-1396
  • Consistent performance in high and low strength concrete
  • Nominal drill bit si
  • One-piece, wrap-around clip ensures uniform holding capacity
  • Nominal drill bit size is the same as the anchor diameter
  • Anchor can be instal
  • Threaded end is chamfered for ease of starting nut
  • Anchor can be installed through standard fixture holes
  • Available in a wide range of diameters and lengths
  • Anchor design allows for follow-up expansion after setting under tensile loading
  • Length ID code and i
  • Carbon steel ASTM A563 grade A nut
  • Length ID code and identifying marking stamped on head of each anchor
  • Anchor design allows
  • The minimum concrete thickness is 1-1/2 times the embedment depth
  • Anchor design allows for follow-up expansion after setting under tensile loading ultimate
  • Normal weight concre
  • The allowable loads are based on a safety factor of 4
  • Normal weight concrete, structural sand-light weight concrete, concrete over steel deck an
  • 11/16 in minimum fixture hole
  • 90 ft-lb installation torque
  • 4520 lb at 2000 psi/8600 lb at 4000 psi ultimate tension loads and 1130 lb at 2000 psi, 16
  • 8720 lb at 2000 psi ultimate shear loads and 1620 lb at 2000 psi, 1900 lb at 3000 psi, 218
  • Anchor body material meets minimum 70000 psi tensile strength
Consistent performance in high and low strength concrete
Code listed under IBC/IRC for grout-filled CMU per ICC-ESESR-1396
Consistent performance in high and low strength concrete
Nominal drill bit size is the same as the anchor diameter
One-piece, wrap-around clip ensures uniform holding capacity
Nominal drill bit size is the same as the anchor diameter
Anchor can be installed through standard fixture holes
Threaded end is chamfered for ease of starting nut
Anchor can be installed through standard fixture holes
Available in a wide range of diameters and lengths
Anchor design allows for follow-up expansion after setting under tensile loading
Length ID code and identifying marking stamped on head of each anchor
Carbon steel ASTM A563 grade A nut
Length ID code and identifying marking stamped on head of each anchor
Anchor design allows for follow-up expansion after setting under tensile loading ultimate pullout 5440 lb
The minimum concrete thickness is 1-1/2 times the embedment depth
Anchor design allows for follow-up expansion after setting under tensile loading ultimate pullout 5440 lb
Normal weight concrete, structural sand-light weight concrete, concrete over steel deck and grouted concrete masonry are applicable materials
The allowable loads are based on a safety factor of 4
Normal weight concrete, structural sand-light weight concrete, concrete over steel deck and grouted concrete masonry are applicable materials
11/16 in minimum fixture hole
90 ft-lb installation torque
4520 lb at 2000 psi/8600 lb at 4000 psi ultimate tension loads and 1130 lb at 2000 psi, 1640 lb at 3000 psi, 2150 lb at 4000 psi for concrete
8720 lb at 2000 psi ultimate shear loads and 1620 lb at 2000 psi, 1900 lb at 3000 psi, 2180 lb at 4000 psi for concrete
Anchor body material meets minimum 70000 psi tensile strength